How to Maintain Our Essential Oil Diffusers?

How to maintain our essential oil diffusers to enhance the use quality and prolong its service life?According to the reviews from our customers, we summarize some tips for the diffusers users,hope these will help you.

Attention:I write the article with our 500ml diffuser as the example.Refer to your machine instructions and oil instructions before using your diffusers.

123

125

124

The Amazon price: $29.99

About the Product

Larger Capacity: Large 500ml water capacity runs for up to 8 hours in high mist mode and 17 hours in low mist mode continuously. Scent a 430 square feet room and humidify a large 270 square feet room.

Timer Setting and Mist Control: 4 timer- 60/ 120/ 180/ Continuous modes. High/ Low button to set strong or weak mist. Long Press the Mist button to turn off the whole unit, including Lighting.

Romantic Night-Light: Press the LIGHT button to shift from one color to another or set it on a specific color. Long press the Light button to turn off the light without affecting the mist.

Quiet and Auto Shut Off: It runs so quietly that you barely notice it. Waterless Auto shut off ensures its safety.

Buy at Amazon

OPERATION

1.please put the product upside,and remove the upper cover.

2.Please connect the AC adapter to the base of DC jack of the main body via cable guide.

3.Please fill in the water and essential oil carefully.

  • pay attention to the filled water level;Do not exceed the max line on the water tank.
  • Water with high temperature and the mist may fly out,please never fill in water during operating.

4.Drop essential oil into water tank carefully. The dosage is about 2-3 drops(about 0.1-0.15ml)

5.Install the cover of the main body with the original channel.

BTW:You must cover the upper cover when you want to use the product.

6,Please connect the AC adaptor with family user power supply socket .

7.Press the switch for mist function.

8.If you do not use it for a long time,please drain out the water from tank water, dry and then keep it well .If you want to use it again,please use the neutral detergent to clean the water tank again,then you can use it.(From the last video ,we come to the conclusion that the warm water can clean the essential oil diffuser ,including the oil smell.BUT if you use the it 5-6 times ,the meutral detergent is the best choice which can clean the Ultrasonic vibration piece.)

ATTENTION

  • The amount and intensity of mist produced will vary,but this is not unusual and should not be considered as a fault.
  • Factors that affect this include water type,humidity,tempErature,air currents.
  • If there is no water in the tank,pressing the MIST will cause the unit to “beep”3 times to remind you to add water.The unit will not work without water.
  • Only 100% natural essential oil can be used in this product .Those containing chemical fragrance,spice or impurities will cause malfuncition.Use 2 or 3 dpops of essential oil per 120ML water a time(Refer to your essential oil instructions) .Too much oil will clog the system and cause malfunction.Please clean the unit as per the maintenance instructions,before changing to use a new type of essential oil.

ACCIDENTAL LEAKAGE

In the event of the unit being knocked over or tipped during use,please follow the steps as below to avoid malfunction.

  • Unplug the unit and remove cover.
  • Pour out any remaining water from the water tank.
  • Shake the unit gently to drain any water inside the mechanism,and then allow drying for at least 24 hours.

(Maybe we could use the hair dryer dry it carefully.)

PERCAUTIONS

  • Please check below to avoid malfunction of the unit.
  • Do not fill over 500ML “MAX”at any time.
  • Do not swith on power when the tank is empty.
  • Do not touch the Ultrasonic vibration plate.
  • Clean regularly as per Maintenance instructions to avoid malfunction.
  • Always unplug from power supply before maintenance.
  • For hygiene reasons,after use ,pour away remaining water from “DRAIN SIDE”of tank,and wipe with a clean dry cloth.
  • Essential oils can stain.In the event of spillage of contact ,please wipe away with a soft cloth .
  • Do not let mist blow directing sunshine heat sources and air conditioners or fans.
  • Always keep on stable flat surface do not place on carpet ,duvet or unstable area.
  • Keep away from electronic equipment,such as TV and Audio equipment .
  • Do not tip the product this may cause water to enter the mechanism and cause malfunction.
  • Do not use for more than 2 hours any time.
  • Wait 60 minutes before restart to avoid damage to Ultrasonic plate.
  • The amount and intensity of mist produced will vary,but this is not unusual and should nor be considered as a fault.
  • Factors that affect this include water type,temperature ,air current.
  • Never move product in use.
  • Do not touch any part of the product with wet hands.
  • Keep out of reach of children and pets.Also,children should be supervised not to play with the product.Appliance is not to be used by children or persons with reduced physical ,sensory or mental capabilities,or lack of experience and knowledge ,unless they have been given supervision or instruction.Keep cord clear of pathways ,and do not pull forcefully at any point .If smoke or burining smell is detected,unplug immediately.

 

It will be better if you follow the instructions in using the diffusers.

 

Leave A Comment

Follow us on Facebook

Top